Optics

 
Pleas use the tabs to display the product type (Experiments, Sets, Products or Lit./Softw.).
 

Page 2 of 5

  <<  Back    1  2  3  4  5    Next page  >>

Colour dispersion with a prism (on the magnetic board)

 
Details

Product-No: P1436301

Measuring the velocity of light - new version

Principle

The intensity of the light is modulated and the phase relationship of the transmitter and receiver signal compared. The velocity of light is calculated from the relationship between the changes in the phase and the light path.

Tasks

  1. To ...
 
Details

Product-No: P2210101

Measuring the velocity of light using the software measure

Principle

The intensity of the light is modulatedand the phase relationship of the transmitter and receiver signal compared. Thevelocity of light is calculated from therelationship between the changes in thephase and the light path.

Tasks

 
Details

Product-No: P2210111

Law of lenses and optical instruments

Principle

The focal lengths of unknown lenses are determined by measuring the distances of image and object and by Bessel's method. Simple optical instruments are then constructed with these lenses.

Tasks

  1. To determine ...
 
Details

Product-No: P2210200

Dispersion and resolving power of a prism and a grating spectroscope

Principle

The refractive indices of liquids, crown glass and flint glass are determined as a function of the wave length by refraction of light through the prism at minimum deviation. The resolving power of the glass prisms is determined from the dispersion curve.

...

 
Details

Product-No: P2210300

Interference of light

Principle

By dividing up the wave-front of a beam of light at the Fresnel mirror and the Fresnel biprism, interference is produced. The wavelength is determined from the interference patterns.

Tasks

Determination of the wavelength of light by interferen ...

 
Details

Product-No: P2220100

Newton's rings with interference filters

Principle

In a Newton's rings apparatus, monochromatic light interferes in the thin film of air between the slightly convex lens and a plane glass plate. The wavelengths are determined from the radii of the interference rings.

Tasks

Using the Newton's r ...

 
Details

Product-No: P2220200

Newton's rings with optical base plate

Principle

The air wedge formed between slightly convex lens and a plane glass plate (Newton's colour glass) is used to cause interference of monochromatic light. The wavelength is determined from the radii of the interference rings.

Tasks

The diameters ...

 
Details

Product-No: P2220205

Interference at a mica plate according to Pohl

Principle

Monochromatic light falls on a plane parallel mica plate. The light rays, reflected at the front surface as well as at the rear surface, will interfere to form a pattern of concentric rings. The radii of the rings depend on the geometry of the experimental setup, th ...

 
Details

Product-No: P2220300

Structure of a Fresnel zone / zone plate

Principle

A zone plate is illuminated with parallel laser light. The focal points of several orders of the zone plate are projected on a ground glass screen.

Tasks

  1. The laser beam must be widened so that the zone plate is well illuminated. It must ...
 
Details

Product-No: P2220400

Michelson interferometer

Principle

In the Michelson arrangement interference will occur by the use of 2 mirrors. The wavelength is determined by displacing one mirror using the micrometerscrew.

Tasks

Determination of the wavelength of the light of th ...

 
Details

Product-No: P2220500

Michelson interferometer with optical base plate

Principle

In a Michelson interferometer, a lightbeam is split into two partial beams by a semi transparent glass plate (amplitude splitting). These beams are reflected by two mirrors and brought to interference after they passed through the glass plate a second time.

 
Details

Product-No: P2220505

Coherence and width of spectral lines with the Michelson interferometer

Principle

The wavelengths and the corresponding lengths of coherence of the green spectral lines of an extreme high pressure Hg vapour lamp are determined by means of a Michelson interferometer. Different double slit combinations are illuminated to verify the coherence condit ...

 
Details

Product-No: P2220600

Refraction index of air and CO2 with the Michelson interferometer

Principle

A measurement cuvette set in the beam path of a Michelson interferometer can be evacuated or filled with CO2. The refraction indexes of air or CO2 are determined through the assessed modification of the interference pattern.

What you can learn abou ...

 
Details

Product-No: P2220700

Refraction index of CO2 with the Michelson interferometer

Principle

Light is caused to interfere by means of a beam splitter and two mirrors according to Michelson's set up. Substituting the air in a measurement cuvette located in one of the interferometer arms by CO2 gas allows to determine the index of re ...

 
Details

Product-No: P2220705

Page 2 of 5

  <<  Back    1  2  3  4  5    Next page  >>

X-ray expert unit

This product is a world first

PHYWE presents the new x-ray unit: innovative technology, top safety, maximum comfort!

More