A polycrystalline powder sample of lead dioxide is irradiated with the radiation from a X-ray tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect the radiation that is constructively reflected from the various ...
A cubic crystalline powder sample is irradiated with the radiation from a X-ray tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect the radiation that is constructively reflected from the various lattice planes ...
A polycrystalline, cubic face-centered crystallizing powder sample is irradiated with the radiation from a Roentgen tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect the radiation that is constructively refle ...
A polycrystalline, cubic face-centered crystallizing copper powder sample and a thin copper sheet are separately irradiated with the radiation from a Roentgen tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect ...
Various metal samples are subjected to polychromatic X-rays. The resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser. The maxima of intensity of the corresponding characteristic X-ray line ...
Various metal samples are subjected to polychromatic X-rays. The resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser. The energy of the characteristic X-ray lines and their full widths at ...
Fluorescence radiation of the elements of a sample can cause fluorescence radiation inside the detector and its housing if the energy is sufficiently high. As a result, the spectrum may include lines that are not caused by the sample. For the detectio ...
Various metal samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser. The energy of the corresponding characteristic X-ray lin ...
The composition of various alloys is analysed with the aid of polychromatic X-rays. The energy of the characteristic fluorescence lines of the alloy constituents is analysed with the aid of a semiconductor de-tector and a multichannel analyser. The al ...
Various powder samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray flu ...
Various saturated solutions are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser. The energy of the corresponding characteris ...
Various ore samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray f ...
Various alloyed materials are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray ...
Various solutions, with known element concentrations, are subjected to polychromatic X-rays. The energy and intensity of the resulting fluorescence radiation of the dissolved elements are analysed with the aid of a semiconductor detector and a multic ...
X-ray fluorescence analysis (XRF) is suitable for the non-contact and non-destructive thickness measurement of thin layers as well as for determining their chemical composition. For this type of measurement, the X-ray source and detector are located ...