Geosciences

 
Pleas use the tabs to display the product type (Experiments, Sets, Products or Lit./Softw.).
 

Page 2 of 3

  <<  Back    1  2  3    Next page  >>

Debye-Scherrer diffraction patterns of powder samples with atetragonal lattice structure

Principle

A polycrystalline powder sample of lead dioxide is irradiated with the radiation from a X-ray tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect the radiation that is constructively reflected from the various ...

 
Details

Product-No: P2542401

Debye-Scherrer diffraction patterns with a cubic powder sam-ple

Principle

A cubic crystalline powder sample is irradiated with the radiation from a X-ray tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect the radiation that is constructively reflected from the various lattice planes ...

 
Details

Product-No: P2542501

Diffraction measurements to determine the intensity of De-bye-Scherrer reflexes using a cubic powder sample

Principle

A polycrystalline, cubic face-centered crystallizing powder sample is irradiated with the radiation from a Roentgen tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect the radiation that is constructively refle ...

 
Details

Product-No: P2542601

Debye-Scherrer diffraction measurements for the examination of the texture of rolled sheets

Principle

A polycrystalline, cubic face-centered crystallizing copper powder sample and a thin copper sheet are separately irradiated with the radiation from a Roentgen tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect ...

 
Details

Product-No: P2542701

X-ray energy spectroscopy - calibration of the X-ray energydetector

Principle

Various metal samples are subjected to polychromatic X-rays. The resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser. The maxima of intensity of the corresponding characteristic X-ray line ...

 
Details

Product-No: P2544001

Energy resolution of the X-ray energy detector

Principle

Various metal samples are subjected to polychromatic X-rays. The resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser. The energy of the characteristic X-ray lines and their full widths at ...

 
Details

Product-No: P2544101

Inherent fluorescence radiation of the X-ray energy detector

Principle

Fluorescence radiation of the elements of a sample can cause fluorescence radiation inside the detector and its housing if the energy is sufficiently high. As a result, the spectrum may include lines that are not caused by the sample. For the detectio ...

 
Details

Product-No: P2544201

Qualitative X-ray fluorescence spectroscopy of metalsMoseley's law

Principle

Various metal samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser. The energy of the corresponding characteristic X-ray lin ...

 
Details

Product-No: P2544501

Qualitative X-ray fluorescence analysis of alloyed materials

Principle

The composition of various alloys is analysed with the aid of polychromatic X-rays. The energy of the characteristic fluorescence lines of the alloy constituents is analysed with the aid of a semiconductor de-tector and a multichannel analyser. The al ...

 
Details

Product-No: P2544601

Qualitative X-ray fluorescence analysis of powder samples

Principle

Various powder samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray flu ...

 
Details

Product-No: P2544701

Qualitative X-ray fluorescence analysis of solutions

Principle

Various saturated solutions are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor  detector and a multi-channel analyser. The energy of the corresponding characteris ...

 
Details

Product-No: P2544801

Qualitative X-ray fluorescence analysis of ore samples

Principle

Various ore samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray f ...

 
Details

Product-No: P2544901

Quantitative X-ray fluorescence analysis of alloyed materials

Principle

Various alloyed materials are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser. The energy of the corresponding characteristic X-ray ...

 
Details

Product-No: P2545001

Quantitative X-ray fluorescence analysis of solutions

Principle

Various solutions, with known element concentrations, are subjected to polychromatic X-rays. The energy and intensity of the resulting fluorescence radiation of the dissolved elements are analysed with the aid of a semiconductor detector and a multic ...

 
Details

Product-No: P2545101

X-ray fluorescence spectroscopy ? layer thickness determination

Principle

X-ray fluorescence analysis (XRF) is suitable for the non-contact and non-destructive thickness measurement of thin layers as well as for determining their chemical composition. For this type of measurement, the X-ray source and detector are located ...

 
Details

Product-No: P2545201

Page 2 of 3

  <<  Back    1  2  3    Next page  >>

X-ray expert unit

This product is a world first

PHYWE presents the new x-ray unit: innovative technology, top safety, maximum comfort!

More