Determination of the Michaelis constant

Product No: P1369860

Principle

The enzymatic hydrolysis of urea in an aquous solution yields carbon dioxide and ammonia. The ions of
these compounds increase the conductivity of the solution. The speed of urea hydrolysis, which is
caused by the urease enzyme, can be determined via conductivity measurements at different substrate
concentration levels. The resulting values can then be used for the calculation of the Michaelis constant.




Materiallist (Excerpt) Product Amount
Software Cobra4 - multi-user licence 14550-61 1
Cobra4 Wireless-Link 12601-00 1
Cobra4 Sensor-Unit Conductivity+, Conductivity/ Temperature (Pt1000) 12632-00 1
Conductivity temperature probe Pt1000 13701-01 1
Urease soln.in 50% glycerol,10ml 31924-03 1
Cobra4 Wireless Manager 12600-00 1
Magnetic stirrer Mini / MST 47334-93 1
Micro-l syringe, 100 micro-l 02606-00 1
Retort stand, h 750 mm 37694-00 1
Water, distilled 5 l 31246-81 1
Urea, 250 g 30086-25 1
Erlenmeyer flask, narrow neck, 100 ml, PN 19 36418-00 6
Separator f.magnetic bars 35680-03 1
Pipettor 36592-00 1
Universal clamp 37715-00 1
Boss head 02043-00 1
Volumetric pipette, 50 ml 36581-00 1
Glass beaker DURAN®, tall, 100 ml 36002-00 6
Volumetric pipette, 20 ml 36579-00 1
Microspoon, steel 33393-00 1
Magnetic stirring bar 30 mm, cylindrical 46299-02 1
Wash bottle, plastic, 500 ml 33931-00 1
Beaker, 250 ml, low form, plastic 36013-01 1
Rubber stopper, d=22/17 mm, without hole 39255-00 6

Literature for this article als follows

Title Product Language
Demo advanced Biology Manual Cobra4Biochemistry & plant physiology 01331-02 ENG
Demo advanced Biologie Handbuch Cobra4 Biochemie & Pflanzenphysiologie 01331-01 DEU

back to corresponding listview

Product No: P1369860