Installing a gas separation column in the glass jacket creates an educationally vivid set-up for demonstrating the main operating principles of a gas chromatograph while at the same time achieving good separation in the low-temperature range of up to 100°C. Dinonyl phthalate on diatomaceous earth is used as the separating agent.
Helium is used as the mobile phase. A soap bubble flow meter is used to set and monitor the flow velocity.
A thermal conductivity detector is used for detection. The signals are passed along via a control unit for recording on a Yt recorder or to an interface.
To control the temperature of the gas separation column, the glass jacket is connected to the external circuit of a circulation thermostat.
This set/up makes it possible to separate both gas mixtures and liquid mixtures.
If an interface for recording the signals is to be used instead of the Yt recorder shown here, the recorder must be replaced with the following equipment:
| Materiallist (Excerpt) |
Product |
Amount |
|
Set of Precision Balance Sartorius CPA 623S and measure software, 230 V
|
49224-88
|
1
|
|
Recorder, tY, 2 channel
|
11415-95
|
1
|
|
Immersion thermostat Alpha A, 230 V
|
08493-93
|
1
|
|
Control unit gas chromatograph
|
36670-99
|
1
|
|
Steel cylinder Helium, 2l, filled
|
41776-00
|
1
|
|
Glass jacket
|
02615-00
|
1
|
|
Dinonyl phthalate, 100 ml
|
31276-10
|
1
|
|
Mesure probe for gas chromatograph, BNC contact
|
36670-10
|
1
|
|
Gas separation column
|
36670-00
|
1
|
|
Microliter syringe, 10 micro-l
|
02607-00
|
1
|
|
Sec.bottle500ml,2xGl18/8,1x25/12
|
34170-01
|
1
|
|
Gas bar
|
40466-00
|
2
|
|
Bath for thermostat, Makrolon
|
08487-02
|
1
|
|
Reducing valve for CO2 / He
|
33481-00
|
1
|
|
Compressed gas, n-butane, 510 g
|
41773-11
|
1
|
|
Compressed gas, iso-butane, 490 g
|
41773-12
|
1
|
|
Table stand f.2 l steel cylinders
|
41774-00
|
1
|
|
Stop clock,demo.;diam. 13 cm
|
03075-00
|
1
|
|
Fine control valve
|
33499-00
|
1
|
|
Chromosorb, PAW, 80/100 Mesh, 20 g
|
31514-04
|
1
|
|
Butane burner, Labogaz 206 type
|
32178-00
|
1
|
|
External circulation set for thermostat Alpha A
|
08493-02
|
1
|
|
Ethyl alcohol, absolute 500 ml
|
30008-50
|
1
|
|
Spring manometer, 0...-1000 mbar
|
34170-02
|
1
|
|
Cyclohexane 1000ml
|
31223-70
|
1
|
|
Quartz glass wool 10 g
|
31773-03
|
1
|
|
Soap bubble flow meter
|
36675-00
|
1
|
|
Tert-butanol for synth. 1000 ml
|
31153-70
|
1
|
|
Water jet pump, plastic
|
02728-00
|
1
|
|
Isopropyl alcohol, 1000 ml
|
30092-70
|
1
|
|
Connecting tube,IGJ29/32-GL18/8
|
35678-02
|
1
|
|
Stopcock,3-way,t-shaped, glass
|
36731-00
|
1
|
|
n-pentane 250 ml
|
31707-25
|
1
|
|
Teflon sleeve IGJ 29, 10 pcs
|
43617-00
|
1
|
|
Acetone, chem.pure 250 ml
|
30004-25
|
1
|
|
Methanol 500 ml
|
30142-50
|
1
|
|
Wrench for steel cylinders
|
40322-00
|
1
|
|
Diethyl ether 250 ml
|
30007-25
|
1
|
|
Support rod, stainless steel, l = 600 mm, d = 10 mm
|
02037-00
|
2
|
|
Test tube rack for 12 tubes, holes d= 22 mm, wood
|
37686-10
|
1
|
|
Round-bott.flask, 500ml,IGJ 29/32
|
35862-00
|
1
|
|
Universal clamp
|
37715-00
|
4
|
|
Test tube, 160 x 16 mm, 100 pcs
|
37656-10
|
1
|
|
Lab thermometer,-10..+150C
|
38058-00
|
1
|
|
Pasteur pipettes, 250 pcs
|
36590-00
|
1
|
|
Lab protecting glasses with UV filter
|
39315-00
|
1
|
|
Rubber tubing,vacuum,i.d.6mm
|
39286-00
|
2
|
|
Right angle clamp
|
37697-00
|
4
|
|
Rubber caps, pack of 20
|
02615-03
|
1
|
|
Connecting cord, 32 A, 750 mm, red
|
07362-01
|
1
|
|
Connecting cord, 32 A, 750 mm, blue
|
07362-04
|
1
|
|
Rubber caps, 10 pcs
|
39275-03
|
1
|
|
Glass tube, straight, l=80 mm, 10/pkg.
|
36701-65
|
1
|
|
Stopper,IGJ 29/32,glass,clear
|
41256-10
|
1
|
|
Silicone tubing i.d. 7mm
|
39296-00
|
4
|
|
Spoon, special steel
|
33398-00
|
1
|
|
Syringe 1ml, Luer, 10 pcs
|
02593-03
|
1
|
|
Cannula 0,45x13 mm, Luer, 20 pcs
|
02598-04
|
1
|
|
Funnel, glass, top dia. 55 mm
|
34457-00
|
1
|
|
Butane cartridge C206, without valve
|
47535-00
|
1
|
|
Hose clip, diam. 8-16 mm, 1 pc.
|
40996-02
|
4
|
|
Hose clip f.12-20 diameter tube
|
40995-00
|
2
|
|
Rubber stopper,d=18/14mm,w/o hole
|
39254-00
|
1
|