The solar ray collector is illuminated with a halogen lamp of
known light intensity. The heat energy absorbed by the collector
can be calculated from the volume flow and the difference in the
water temperatures at the inlet and outlet of the absorber, if the
inlet temperature stays almost constant by releasing energy to a
reservoir. The efficiency of the collector is determined from this.
The measurement is made with various collector arrangements and at
various absorber temperatures.
To determine the efficiency of the solar ray collector under
various experimental conditions.
| Materiallist (Excerpt) |
Product |
Amount |
|
Solar ray collector
|
06753-00
|
1
|
|
Circulating pump w.flowmeter
|
06754-01
|
1
|
|
Halogen lamp 1000 W
|
08125-93
|
1
|
|
Power supply 0...12 V DC/ 6 V, 12 V AC, 230 V
|
13505-93
|
1
|
|
Heat exchanger
|
06755-00
|
1
|
|
Solar collector stand, teaching aid
|
06757-00
|
1
|
|
Tripod base PHYWE
|
02002-55
|
2
|
|
Hot/cold air blower, 1800 W
|
04030-93
|
1
|
|
Glass beaker, short, 5000 ml
|
36272-00
|
1
|
|
Stopwatch, digital, 1/100 s
|
03071-01
|
1
|
|
Support rod PHYWE,square,l 250mm
|
02025-55
|
2
|
|
Right angle clamp PHYWE
|
02040-55
|
2
|
|
Glass beaker DURAN®, tall, 2000 ml
|
36010-00
|
1
|
|
Immersion heater,1000W,220-250V
|
04020-93
|
1
|
|
Lab thermometer,w.stem,-10..+110C
|
38060-00
|
1
|
|
Universal clamp
|
37718-00
|
1
|
|
Lab thermometer,-10..+100C
|
38056-00
|
2
|
|
Safety gas tubing, DVGW, sold by metre
|
39281-10
|
3
|
|
Measuring tape, l = 2 m
|
09936-00
|
1
|
|
Connecting cord, 32 A, 750 mm, red
|
07362-01
|
1
|
|
Connecting cord, 32 A, 750 mm, blue
|
07362-04
|
1
|
|
Laboratory Experiments Physics, Chemistry, Biology andApplied Sciences, CD-ROM, incl. operating manuals
|
16502-42
|
1
|