The Stirling engine is submitted to a load by means of an adjustable torquemeter, or by a coupled generator. Rotation frequency and temperature changes of the Stirling engine are observed. Effective mechanical energy and power, as well as effective electrical power, are assessed as a function of rotation frequency. The amount of energy converted to work per cycle can be determined with the assistance of the pV diagram. The efficiency of the Stirling engine can be estimated.
| Materiallist (Excerpt) |
Product |
Amount |
|
Meter for Stirling engine, pVnT
|
04371-97
|
1
|
|
Stirling engine transparent
|
04372-00
|
1
|
|
Cobra3 BASIC-UNIT, USB
|
12150-50
|
1
|
|
Sensor unit pVn for Stirling engine
|
04371-00
|
1
|
|
Torque meter
|
04372-02
|
1
|
|
Motor/ generator unit
|
04372-01
|
1
|
|
Thermocouple NiCr-Ni, sheathed
|
13615-01
|
2
|
|
Power supply 12V / 2A
|
12151-99
|
1
|
|
Software Cobra3 Universal recorder
|
14504-61
|
1
|
|
Chimney for stirling engine
|
04372-04
|
1
|
|
Screened cable, BNC, l 750 mm
|
07542-11
|
2
|
|
Denaturated alcohol (spirit for burning), 1000 ml
|
31150-70
|
1
|
|
Adapter, BNC socket/4 mm plug pair
|
07542-27
|
2
|