Faraday's law

Product No: P2411200

Principle

The correlation between the amounts of substances transformed in the electrode reaction and the applied charge (amount of electricity) is described by Faraday´s law. Faraday ´s constant, which appears as a proportionality factor, can be determined experimentally from this dependence.

Tasks

  1. Determine Faraday´s constant from the dependence of the volumes of hydrogen and oxygen evolved on the applied charge in the hydrolysis of diluted sulphuricacid.

What you can learn about

  • Electrolysis
  • Coulometry
  • Charge
  • Amount of substance
  • Faraday´s law
  • Faraday´s contant
  • Avogadro´s number
  • General equation of state for ideal gases



Materiallist (Excerpt) Product Amount
Set of Precision Balance Sartorius TE 612 and measure software balances,230V 48836-88 1
Power supply, universal 13500-93 1
Electrolysis apparatus-Hofmann 44518-00 1
Weather monitor, 6 lines LCD 87997-10 1
Digital multimeter 2010 07128-00 1
On/off switch 06034-01 1
Retort stand, h 750 mm 37694-00 1
Platin.electrode in prot.tube,8mm 45206-00 2
Stopwatch, digital, 1/100 s 03071-01 1
Water, distilled 5 l 31246-81 1
Sulphuric acid, 95-98% 500 ml 30219-50 1
Universal clamp 37715-00 2
Pasteur pipettes, 250 pcs 36590-00 1
Right angle clamp 37697-00 3
Glass beaker DURAN®, short form, 600 ml 36015-00 1
Connecting cord, 32 A, 750 mm, blue 07362-04 1
Rubber caps, 10 pcs 39275-03 1
Connecting cord, 32 A, 500 mm, red 07361-01 1
Connecting cord, 32 A, 250 mm, red 07360-01 2
Funnel, glass, top dia. 80 mm 34459-00 1
Wash bottle, plastic, 500 ml 33931-00 1

Literature for this article als follows

Title Product Language
TESS expert Handbook Laboratory Experiments Physics 16502-32 ENG

back to corresponding listview