An alternating voltage is applied to one of two coils (primary coil) which are located on a common iron core. The voltage induced in the second coil (secondary coil) and the current flowing in it are investigated as functions of the number of turns in the coils and of the current flowing in the primary coil.
| Materiallist (Excerpt) |
Product |
Amount |
|
Multitap transformer, 14 VAC/ 12 VDC, 5 A
|
13533-93
|
1
|
|
Coil, 140 turns, 6 tappings
|
06526-01
|
2
|
|
Rheostat, 10 Ohm , 5.7A
|
06110-02
|
1
|
|
Clamping device
|
06506-00
|
1
|
|
Iron core, U-shaped, laminated
|
06501-00
|
1
|
|
Two-way switch, double pole
|
06032-00
|
1
|
|
DMM with NiCr-Ni thermo couple
|
07122-00
|
3
|
|
Iron core, short, laminated
|
06500-00
|
1
|
|
Connecting cord, 32 A, 500 mm, red
|
07361-01
|
6
|
|
Connecting cord, 32 A, 500 mm, blue
|
07361-04
|
6
|
|
Laboratory Experiments Physics, Chemistry, Biology andApplied Sciences, CD-ROM, incl. operating manuals
|
16502-42
|
1
|