Faraday's laws of electrolysis describe the correlation between
the amounts of substances transformed in the reactions at the
electrodes and the charge applied (amount of electricity).
Faraday's constant, which appears as a proportionality factor, can
be determined experimentally from the dependence.
| Materiallist (Excerpt) |
Product |
Amount |
|
Set of Precision Balance Sartorius CPA 623S and measure software, 230 V
|
49224-88
|
1
|
|
Power supply, universal
|
13500-93
|
1
|
|
Electrolysis apparatus-Hofmann
|
44518-00
|
1
|
|
Weather monitor, 6 lines LCD
|
87997-10
|
1
|
|
Digital multimeter 2010
|
07128-00
|
1
|
|
On/off switch
|
06034-01
|
1
|
|
Retort stand, h 750 mm
|
37694-00
|
1
|
|
Platin.electrode in prot.tube,8mm
|
45206-00
|
2
|
|
Stopwatch, digital, 1/100 s
|
03071-01
|
1
|
|
Water, distilled 5 l
|
31246-81
|
1
|
|
Sulphuric acid, 95-98% 500 ml
|
30219-50
|
1
|
|
Universal clamp
|
37715-00
|
2
|
|
Pasteur pipettes, 250 pcs
|
36590-00
|
1
|
|
Right angle clamp
|
37697-00
|
3
|
|
Glass beaker DURAN®, short form, 600 ml
|
36015-00
|
1
|
|
Connecting cord, 32 A, 750 mm, blue
|
07362-04
|
1
|
|
Rubber caps, 10 pcs
|
39275-03
|
1
|
|
Connecting cord, 32 A, 500 mm, red
|
07361-01
|
1
|
|
Connecting cord, 32 A, 250 mm, red
|
07360-01
|
2
|
|
Funnel, glass, top dia. 80 mm
|
34459-00
|
1
|
|
Wash bottle, plastic, 500 ml
|
33931-00
|
1
|
|
Laboratory Experiments Physics, Chemistry, Biology andApplied Sciences, CD-ROM, incl. operating manuals
|
16502-42
|
1
|