Resistor-Capacitor (RC) circuits serve as filters for
frequencies. The frequency response of the most commonly used RC
filters is recorded by point-by-point measurements as well as the
frequency sweep method, and displayed on the oscilloscope. The
results are plotted and verified using the measure analysis
software.
| Materiallist (Excerpt) |
Product |
Amount |
|
Digital Function Generator, USB, incl. Cobra4 Software
|
13654-99
|
1
|
|
25 MHz Digital storage oscilloscope with colour display, 2 x BNC cables l =75 cm incl.
|
11456-99
|
1
|
|
Difference amplifier
|
11444-93
|
1
|
|
Plug-in board,4mm plugs
|
06033-00
|
1
|
|
Resistor 500 Ohm 2%, 1W, G1
|
06057-50
|
1
|
|
Capacitor 10nF/ 250V, G1
|
39105-14
|
4
|
|
Resistor 1kOhm, 1W, G1
|
39104-19
|
5
|
|
Screened cable, BNC, l 1500 mm
|
07542-12
|
2
|
|
Connector, T type, BNC
|
07542-21
|
1
|
|
Screened cable, BNC, l 750 mm
|
07542-11
|
2
|
|
Adapter, BNC-plug/socket 4 mm.
|
07542-26
|
2
|
|
Connecting plug white 19 mm pitch
|
39170-00
|
5
|
|
Connecting cord, 32 A, 500 mm, red
|
07361-01
|
2
|
|
Connecting cord, 32 A, 500 mm, blue
|
07361-04
|
3
|
|
Connecting cord, 100 mm, yellow
|
07359-02
|
1
|
|
Laboratory Experiments Physics, Chemistry, Biology andApplied Sciences, CD-ROM, incl. operating manuals
|
16502-42
|
1
|