Self-induction when switching acircuit off
Principle
In the last experiment, the students learned that self-induced
voltage is formed in a coil when a direct current circuit
is closed, and that this self-induced voltage counteracts the
connected voltage. Now, they should learn that self-induced voltage
formed when a circuit is opened has the same direction as the
original (i.e. connected) voltage.
If the students can already predict the results of the first
experiment based on their knowledge of the laws of induction and
Lenz's Law, then they should carry out the experiment to confirm
their prediction nevertheless. Furthermore, the second experiment
should demonstrate that self-induced voltage can attain values that
greatly exceed the original voltage.
Benefits
- No additional cable connections between the building blocks needed - clear arragned and quick setup
- Contact saftey due to puzzle blocks system
- Corrosion-free gold plated contacts
- Doubled earning sucess: Electric circuit diagram on top, real components can be seen unterside
Tasks
What effect does a coil have when the circuit
is opened?
Investigate the direction of the self-induced voltage produced
when a direct current circuit is opened.
Scope of delivery
|
Straight connector module, SB
|
05601-01
|
1
|
|
Angled connector module, SB
|
05601-02
|
4
|
|
T-shaped connector module, SB
|
05601-03
|
2
|
|
Interrupted connector module with sockets, SB
|
05601-04
|
2
|
|
Junction module, SB
|
05601-10
|
2
|
|
On-off switch module, SB
|
05602-01
|
1
|
|
Change-over switch module, SB
|
05602-02
|
1
|
|
Socket module for incandescent lamp E10, SB
|
05604-00
|
1
|
|
Coil, 1600 turns
|
07830-01
|
1
|
|
Iron core, U-shaped, laminated
|
07832-00
|
1
|
|
Iron core, I-shaped, laminated
|
07833-00
|
1
|
|
Tightening screw
|
07834-00
|
1
|
|
Neon lamp 110 V AC, E10
|
07506-90
|
1
|
|
Connecting cable, 32 A, red, various lengths
|
07360-01
|
1
|
|
Connecting cable, 32 A, blue, various lengths
|
07360-04
|
1
|
|
Connecting cable, 32 A, red, various lengths
|
07361-01
|
2
|
|
Connecting cable, 32 A, blue, various lengths
|
07361-04
|
2
|
|
PHYWE Power supply, 230 V,DC: 0...12 V, 2 A / AC: 6 V, 12 V, 5 A
|
13506-93
|
1
|
|
PHYWE Analog multimeter, 600V AC/DC, 10A AC/DC, 2 MΩ, overload protection
|
07021-11
|
1
|
|