Technical data


Determination of the mixing enthalpy with Cobra SMARTsensethalpy of binary fluid mixtures with CobraSMARTsense

Article no: P3020667

Principle

When two miscible liquids are mixed, a positive or negative heat effect occurs, which is caused by the interactions between the molecules. This heat effect is dependent on the mixing ratio. The integral mixing enthalpy and the differential molar mixing enthalpy can be determined by calorimetric measurements of the heat of reaction.

Benefits

  • Part of a system solution - Easily expandable for further experiments
  • Calorimeters with particularly high capacitance
  • Simplified implementation: all pre-settings already prepared

Tasks

  1. Measure the integral mixing enthalpy of seven different water-acetone mixtures.
  2. Plot the molar integral mixing enthalpy versus the quantity of substance (mole fraction) and determine the molar mixing enthalpy.
  3. Discuss the results on the basis of the interactions in the mixture.

Learning objectives

  • Differential molar mixing enthalpy
  • Real and ideal behaviour
  • Integral molar mixing enthalpy
  • Fundamental principles of thermodynamics
  • Calorimetry

Necessary accessories

  • Precision balance 6200g/0.01g

Scope of delivery

Cobra SMARTsense Voltage - Sensor for measuring electrical voltage ± 30 V (Bluetooth + USB) 12901-01 1
Cobra SMARTsense High Current - Sensor for measuring electric current ± 10 A (Bluetooth + USB) 12925-00 1
measureLAB, multi-user license 14580-61 1
Calorimeter, transparent, 1200 ml 04402-00 1
Heating coil with sockets 04450-00 1
PHYWE Power supply, universal, analog display DC: 18 V, 5 A / AC: 15 V, 5 A 13503-93 1
Connecting cable, 32 A, black, various lengths 07361-05 6
Magnetic stirrer with heater MR Hei-Standard 35753-93 1
Magnetic stirring bar 30 mm, oval 35680-04 1
Separator for magnetic bars 35680-03 1
Supp.rod stainl.st.,50cm,M10-thr. 02022-20 1
Retort stand, h = 750 mm 37694-00 1
Right angle boss-head clamp 37697-00 3
Universal clamp 37715-01 3
Immersion thermostat Alpha A, 230 V 08493-93 1
External circulation set for thermostat Alpha A 08493-02 1
Bath for thermostat, makrolon 08487-02 1
Rubber hose, various diameters 39282-00 3
Hose clip, diam. 8-16 mm, 1 pc. 40996-02 4
Erlenmeyer flask, stopper bed, 250 mlSB 29 MAU-EK17082306 2
Erlenmeyer flask, stopper bed, 100 mlSB 19 MAU-EK17082002 5
Funnels (glass), Boro, various sizes 34459-00 1
Powder funnels, plastic, various sizes 34472-00 1
Wash bottle, plastic, 500 ml 33931-00 1
Pasteur pipettes, 250 pcs 36590-00 1
Rubber caps, 10 pcs 39275-03 1
Acetone, chemical pure, 250 ml 30004-25 6
Water, distilled 5 l 31246-81 1
Cobra SMARTsense Temperature - Sensor for measuring temperature -40 ... 120 °C (Bluetooth) 12903-00 1

PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10 – 37079 Göttingen – Germany
www.phywe.com