Technical data Efficiency of the pump in the conversion of electric energy to potential energyArticle no: P9518300 ![]()
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
Principle The efficiency attained in this experiment, only 2 % to 3 %, is very low compared to that of pumps used in practice, which can reach 20 % to 90 %. This difference is mainly due to the size of the pump and, in particular and despite the small scale of it, the fact that the robustness needed for the stability of the rotor is attained at the cost of the performance. The purpose of this experiment is to bring home the efficiency calculation. Benefits
Tasks How efficiently does the pump work?
Scope of delivery
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10 – 37079 Göttingen – Germany
www.phywe.com
Robert-Bosch-Breite 10 – 37079 Göttingen – Germany
www.phywe.com